XLPE Insulated PVC Sheathed Power Cable Flame Retardant 0.6 / 1KV CU / XLPE / PVC Conductor Working Temperature 90 Celsius
Special Features will be available when required:
Fire Resistance
Oil Resistance
Retardant Flame Cat. A,B,C
Heat Resistance
Low Smoke Zero Halogen
Dimension& Electrical Data:
NYBY 1x (1.5-500)mm2 0.6/1kV | |||||
cross section (mm2) | outer diameter approx. (mm) | weight of cable approx (kg/km) | maximum DC resistance at 20℃ (Ω/km) | min bending radius (mm) | current rating in air at 25℃ (A) |
1×1.5 | 5.8 | 48.7 | |||
1×2.5 | 6.2 | 60.8 | |||
1×4 | 6.7 | 78.4 | |||
1×6 | 7.2 | 100.4 | |||
1×10 | 8.1 | 156.3 | 1.83 | 164 | 98 |
1×16 | 9.6 | 212.5 | 1.15 | 184 | 132 |
1×25 | 11.3 | 310.8 | 0.727 | 216 | 187 |
1×35 | 12.4 | 407.4 | 0.524 | 236 | 217 |
1×50 | 14 | 522.5 | 0.387 | 266 | 263 |
1×70 | 15.9 | 727.1 | 0.268 | 306 | 331 |
1×95 | 17.2 | 994.4 | 0.193 | 342 | 408 |
1×120 | 18.8 | 1222.8 | 0.153 | 374 | 474 |
1×150 | 21 | 1523.1 | 0.124 | 418 | 550 |
1×185 | 23 | 1860 | 0.0991 | 458 | 633 |
1×240 | 25.6 | 2405.9 | 0.0754 | 510 | 750 |
1×300 | 28.2 | 2997.4 | 0.0601 | 564 | 871 |
1×400 | 32 | 3838.9 | 0.047 | 640 | 1000 |
1×500 | 35.6 | 4877 | 0.0366 | 708 | 1150 |
NYBY 2x (1.5-240)mm2 0.6/1kV | |||||
cross section (mm2) | outer diameter approx. (mm) | weight of cable approx (kg/km) |
maximum DC resistance at 20℃ (Ω/km) |
min bending radius (mm) | current rating in air at 25℃ (A) |
2×1.5 | 10.1 | 122.1 | 12.1 | 138 | 27 |
2×2.5 | 10.9 | 150.9 | 7.41 | 159 | 36 |
2×4 | 11.9 | 192.7 | 4.61 | 174 | 48 |
2×6 | 12.9 | 243.7 | 3.08 | 189 | 61 |
2×10 | 15.7 | 346.5 | 1.83 | 228 | 83 |
2×16 | 17.9 | 509.4 | 1.15 | 249 | 113 |
2×25 | 21.3 | 743.4 | 0.727 | 297 | 150 |
2×35 | 23.5 | 964.5 | 0.524 | 258 | 186 |
2×50 | 18.7 | 1046.1 | 0.387 | 291 | 226 |
2×70 | 21.5 | 1447.7 | 0.268 | 330 | 290 |
2×95 | 24.1 | 1984 | 0.193 | 369 | 353 |
2×120 | 26.7 | 2469.4 | 0.153 | 411 | 413 |
2×150 | 29.7 | 3056.8 | 0.124 | 453 | 468 |
2×185 | 32.7 | 3746.1 | 0.0991 | 510 | 540 |
2×240 | 36.9 | 4871.1 | 0.0754 | 605 | 590 |
NYBY 3x (1.5-300)mm2 0.6/1kV | |||||
cross section (mm2) | outer diameter approx.(mm) | weight of cable approx (kg/km) |
maximum DC resistance at 20℃ (Ω/km) |
min bending radius (mm) |
current rating in air at 25℃ (A) |
3×1.5 | 10.5 | 142.3 | 12.1 | 152 | 23 |
3×2.5 | 11.4 | 180.6 | 7.41 | 165 | 32 |
3×4 | 12.5 | 236.7 | 4.61 | 180 | 41 |
3×6 | 13.6 | 305.7 | 3.08 | 197 | 52 |
3×10 | 15.6 | 446.8 | 1.83 | 230 | 71 |
3×16 | 19 | 665.2 | 1.15 | 263 | 96 |
3×25 | 22.6 | 983.8 | 0.727 | 315 | 130 |
3×35 | 25 | 1291.2 | 0.524 | 347 | 159 |
3×50 | 22 | 1507.3 | 0.387 | 351 | 193 |
3×70 | 25.6 | 2128.9 | 0.268 | 411 | 245 |
3×95 | 28.6 | 2912.4 | 0.193 | 459 | 302 |
3×120 | 31.6 | 3613.7 | 0.153 | 510 | 349 |
3×150 | 35.5 | 4513.8 | 0.124 | 579 | 400 |
3×185 | 39.1 | 5538.9 | 0.0991 | 650 | 464 |
3×240 | 43.8 | 7182.8 | 0.0754 | 722 | 552 |
3×300 | 48.4 | 8965.6 | 0.0601 | 783 | 640 |
NYBY 4x (1.5-300)mm2 0.6/1kV | |||||
cross section (mm2) | outer diameter approx. (mm) | weight of cable approx (kg/km) |
maximum DC resistance at 20℃ (Ω/km) |
min bending radius (mm) |
current rating in air at 25℃ (A) |
4×1.5 | 11.3 | 168.8 | 12.1 | 23 | |
4×2.5 | 12.3 | 217.6 | 7.41 | 32 | |
4×4 | 13.5 | 289.2 | 4.61 | 195 | 41 |
4×6 | 14.7 | 379.2 | 3.08 | 213 | 52 |
4×10 | 16.9 | 561.7 | 1.83 | 251 | 71 |
4×16 | 20.8 | 843.4 | 1.15 | 287 | 96 |
4×25 | 24.9 | 1255.7 | 0.727 | 348 | 130 |
4×35 | 27.5 | 1658.4 | 0.524 | 378 | 159 |
4×50 | 25.3 | 1996.2 | 0.387 | 383 | 193 |
4×70 | 29.4 | 2819 | 0.268 | 434 | 245 |
4×95 | 32.8 | 3861.6 | 0.193 | 488 | 302 |
4×120 | 36.5 | 4804.5 | 0.153 | 539 | 349 |
4×150 | 40.6 | 5975.4 | 0.124 | 603 | 400 |
4×185 | 45.2 | 7364.2 | 0.0991 | 666 | 464 |
4×240 | 50.7 | 9560.1 | 0.0754 | 741 | 552 |
4×300 | 56 | 11928.8 | 0.0601 | 840 | 640 |
NYBY (3+1)x (4-300)mm2 0.6/1kV | |||||
cross section (mm2) | outer diameter approx.(mm) | weight of cable approx (kg/km) | maximum DC resistance at 20℃ | min bending radius (mm) | current rating in air at 25℃ (A) |
3×4+1×2.5 | 13.2 | 268.3 | 4.61 | 191 | 41 |
3×6+1×4 | 14.4 | 352.1 | 3.08 | 209 | 52 |
3×10+1×6 | 17.3 | 526.4 | 1.83 | 242 | 71 |
3×16+1×10 | 20.1 | 773.1 | 1.15 | 279 | 96 |
3×25+1×16 | 23.9 | 1145.3 | 0.727 | 333 | 130 |
3×35+1×16 | 26 | 1444.7 | 0.524 | 369 | 159 |
3×50+1×25 | 23.9 | 1768.2 | 0.387 | 416 | 193 |
3×70+1×35 | 27.9 | 2489.7 | 0.268 | 479 | 245 |
3×95+1×50 | 31.3 | 3399 | 0.193 | 543 | 302 |
3×120+1×70 | 34.6 | 4303.6 | 0.153 | 599 | 349 |
3×150+1×70 | 38.5 | 5212.1 | 0.124 | 675 | 400 |
3×185+1×95 | 42.9 | 6521.1 | 0.0991 | 741 | 464 |
3×240+1×120 | 48.1 | 8422.2 | 0.0754 | 824 | 552 |
3×300+1×150 | 53 | 10453.4 | 0.0601 | 944 | 640 |
Drum Data:
Certificates:
Tips:
When sending an inquiry about cables or building wires,please address the specification or parameters of cables shown as follows:
Cable name: XLPE Insulated PVC Sheathed Power Cable Flame Retardant 0.6 / 1KV CU / XLPE / PVC Conductor Working Temperature 90 Celsius.
Voltage: 0.6/1 KV
Cross section: for example: 3×120mm² (It means there are three conductors inside this cable and the size of each conductor is 120 square millimeters.)
Length: for example: 1000 meters
Harbor& postcode: for example: Yantian port,Shenzhen,China. 518000
It will save you a lot of time and will also help us to prepare you an accurate quotation very quickly.Thanks!