Flexible Control Cable For Control&Monitoring Purposes 450 / 750V CU / XLPE / PVC IEC 60227-5
Dimension& Electrical Data:
Item | Code | Explanation |
Flame-proof | / | Nonfame-proof(omission) |
characteristics | ZA | Class A fame-proof |
ZB | Class B fame-proof | |
ZC | Class C fame-proof | |
WDZ | Halogen-free and low smoke fame retardant | |
Illustration | Among the bundle-burning test class A,B,C,class A is the best. Low-smoke halogen free cable is also classifed to class A,B,C for example WDZB |
|
Seried code | k | Control cable |
Insulation material | Y | PVC |
YJ | XLPE | |
Sheath material | Y | Low smoke halogen free flame retardant polyolefn |
V | PVC fame-retardant | |
Shield material | P | Copper wire or tinned copper wire braid |
P3 | Composite Aluminum- plastic tape | |
P2 | Copper tape or copper- plastic tape | |
Armour Material | 22 | Steel tape armour and PVC sheath |
23 | Steel tape armour and polyolefin sheath | |
32 | Winding steel wire armour PVC sheath | |
33 | Winding steel wire armour polyolefin sheath | |
Heat-resistant degree | 70 | The highest operating temperature is 70℃(Omission) |
90 | The highest operating temperature is 90℃ | |
Conductor Type | A | Single conductor(class1) |
B | 2stranded conductor(indicated in the bracket behind specifcation forA,Btype) | |
R | Multiple threads stranded conductor(class5) | |
Specifcation | No.of cores×Standard crosssection of conductor mm2 |
No.ofCores Cross-sec.(mm²) | Reference Outer Diameter (mm) | Reference Weight (kg/km) |
Maximum DC Resistance at20℃ (Ω/km) |
Minimum Insulation Resistance at 90℃ (MΩ×km) |
2×0.75 | 7.24 | 62.4 | 24.5 | 1.2 |
2×1 | 7.6 | 70.8 | 18.1 | 1.1 |
2×1.5 | 8.06 | 84.4 | 12.1 | 1.1 |
2×2.5 | 9.2 | 115.3 | 7.41 | 1 |
2×4 | 10.2 | 154.7 | 4.61 | 0.85 |
2×6 | 11.2 | 202.3 | 3.08 | 0.7 |
2×10 | 14.6 | 331.9 | 1.83 | 0.65 |
3×0.75 | 7.59 | 73.8 | 24.5 | 1.2 |
3×1 | 7.98 | 85 | 18.1 | 1.1 |
3×1.5 | 8.47 | 103.3 | 12.1 | 1.1 |
3×2.5 | 9.7 | 143.9 | 7.41 | 1 |
3×4 | 10.78 | 198 | 4.61 | 0.85 |
3×6 | 11.86 | 264 | 3.08 | 0.7 |
3×10 | 15.16 | 434 | 1.83 | 0.65 |
4×0.75 | 8.15 | 88.1 | 24.5 | 1.2 |
4×1 | 8.59 | 102.1 | 18.1 | 1.1 |
4×1.5 | 9.14 | 125.7 | 12.1 | 1.1 |
4×2.5 | 10.52 | 177.5 | 7.41 | 1 |
4×4 | 11.73 | 247.9 | 4.61 | 0.85 |
4×6 | 13.54 | 351.5 | 3.08 | 0.7 |
4×10 | 16.57 | 549.7 | 1.83 | 0.65 |
5×0.75 | 8.76 | 103.2 | 24.5 | 1.2 |
5×1 | 9.25 | 120.5 | 18.1 | 1.1 |
5×1.5 | 9.87 | 149.5 | 12.1 | 1.1 |
5×2.5 | 11.41 | 213.2 | 7.41 | 1 |
5×4 | 12.76 | 299.9 | 4.61 | 0.85 |
5×6 | 14.71 | 425.5 | 3.08 | 0.7 |
5×10 | 18.08 | 669.6 | 1.83 | 0.65 |
7×0.75 | 9.41 | 121.5 | 24.5 | 1.2 |
7×1 | 9.95 | 143.3 | 18.1 | 1.1 |
7×1.5 | 10.64 | 180.9 | 12.1 | 1.1 |
7×2.5 | 12.35 | 261.4 | 7.41 | 1 |
7×4 | 14.45 | 393.5 | 4.61 | 0.85 |
7×6 | 15.95 | 534.4 | 3.08 | 0.7 |
7×10 | 19.7 | 847.7 | 1.83 | 0.65 |
No.ofCores Cross-sec.(mm²) | Reference Outer Diameter (mm) | Reference Weight (kg/km) |
Maximum DC Resistance at 20℃ (Ω/km) |
Minimum Insulation Resistance at90℃ (MΩ×km) |
8×0.75 | 10.39 | 140.5 | 24.5 | 1.2 |
8×1 | 11.01 | 165.9 | 18.1 | 1.1 |
8×1.5 | 11.8 | 209.5 | 12.1 | 1.1 |
8×2.5 | 14.37 | 322.7 | 7.41 | 1 |
8×4 | 16.09 | 455.6 | 4.61 | 0.85 |
8×6 | 17.82 | 619 | 3.08 | 0.7 |
8×10 | 22.53 | 1004.3 | 1.83 | 0.65 |
10×0.75 | 11.58 | 168.4 | 24.5 | 1.2 |
10×1 | 12.3 | 199.6 | 18.1 | 1.1 |
10×1.5 | 13.82 | 272 | 12.1 | 1.1 |
10×2.5 | 16.1 | 390.9 | 7.41 | 1 |
10×4 | 18.1 | 555.7 | 4.61 | 0.85 |
10×6 | 20.5 | 776.5 | 3.08 | 0.7 |
10×10 | 25.5 | 1232.5 | 1.83 | 0.65 |
12×0.75 | 11.93 | 190.8 | 24.5 | 1.2 |
12×1 | 12.68 | 227.6 | 18.1 | 1.1 |
12×1.5 | 14.23 | 310.2 | 12.1 | 1.1 |
12×2.5 | 16.6 | 449.7 | 7.41 | 1 |
12×4 | 18.68 | 644.6 | 4.61 | 0.85 |
12×6 | 21.16 | 903.6 | 3.08 | 0.7 |
14×0.75 | 12.47 | 214.5 | 24.5 | 1.2 |
14×1 | 13.86 | 275.4 | 18.1 | 1.1 |
14×1.5 | 14.88 | 350.3 | 12.1 | 1.1 |
14×2.5 | 17.39 | 510.8 | 7.41 | 1 |
14×4 | 20 | 754.1 | 4.61 | 0.85 |
14×6 | 22.2 | 1034.1 | 3.08 | 0.7 |
16×0.75 | 13.7 | 257.2 | 24.5 | 1.2 |
16×1 | 14.55 | 306.2 | 18.1 | 1.1 |
16×1.5 | 15.63 | 391.1 | 12.1 | 1.1 |
16×2.5 | 18.31 | 572.9 | 7.41 | 1 |
19×0.75 | 14.35 | 292.7 | 24.5 | 1.2 |
19×1 | 15.25 | 350 | 18.1 | 1.1 |
19×1.5 | 16.4 | 449.6 | 12.1 | 1.1 |
19×2.5 | 19.65 | 680.4 | 7.41 | 1 |
No.ofCores Cross-sec. (mm²) | Reference OuterDiameter (mm) | Reference Weight (kg/km) | MaximumDC Resistance at20℃ (Ω/km) | Minimum Insulation Resistance at90℃ (MΩ×km) |
24×0.75 | 16.52 | 360.1 | 24.5 | 1.2 |
24×1 | 17.6 | 431.9 | 18.1 | 1.1 |
24×1.5 | 18.98 | 557.1 | 12.1 | 1.1 |
24×2.5 | 22.8 | 844.9 | 7.41 | 1 |
27×0.75 | 16.85 | 393.2 | 24.5 | 1.2 |
27×1 | 17.95 | 473 | 18.1 | 1.1 |
27×1.5 | 19.77 | 630.4 | 12.1 | 1.1 |
27×2.5 | 23.27 | 931.5 | 7.41 | 1 |
30×0.75 | 17.41 | 428 | 24.5 | 1.2 |
30×1 | 18.56 | 516.1 | 18.1 | 1.1 |
30×1.5 | 20.44 | 688.8 | 12.1 | 1.1 |
30×2.5 | 24.09 | 1021.1 | 7.41 | 1 |
37×0.75 | 18.69 | 509 | 24.5 | 1.2 |
37×1 | 20.35 | 634.6 | 18.1 | 1.1 |
37×1.5 | 21.96 | 824.6 | 12.1 | 1.1 |
37×2.5 | 25.95 | 1229.5 | 7.41 | 1 |
44×0.75 | 21.26 | 616 | 24.5 | 1.2 |
44×1 | 22.7 | 744.3 | 18.1 | 1.1 |
44×1.5 | 24.54 | 969.6 | 12.1 | 1.1 |
44×2.5 | 29.7 | 1489.3 | 7.41 | 1 |
48×0.75 | 21.59 | 659.6 | 24.5 | 1.2 |
48×1 | 23.05 | 798.4 | 18.1 | 1.1 |
48×1.5 | 24.93 | 1043.2 | 12.1 | 1.1 |
48×2.5 | 30.17 | 1604.1 | 7.41 | 1 |
52×0.75 | 22.15 | 705.1 | 24.5 | 1.2 |
52×1 | 23.66 | 854.9 | 18.1 | 1.1 |
52×1.5 | 25.6 | 1118.9 | 12.1 | 1.1 |
52×2.5 | 30.99 | 1722.3 | 7.41 | 1 |
61×0.75 | 23.43 | 807.5 | 24.5 | 1.2 |
61×1 | 25.05 | 981.9 | 18.1 | 1.1 |
61×1.5 | 27.12 | 1289.9 | 12.1 | 1.1 |
61×2.5 | 32.85 | 1988.5 | 7.41 | 1 |
Drum Data:
Certificates:
Tips:
When sending an inquiry about cables or building wires,please address the specification or parameters of cables shown as follows:
Cable name: Flexible Control Cable For Control&Monitoring Purposes 450 / 750V CU / XLPE / PVC IEC 60227-5
Voltage: 450/750 V
Cross section: for example: 3×2.5 mm² (It means there are three conductors inside this cable and the size of each conductor is 2.5 square millimeters.)
Length: for example: 500 meters
Harbor& postcode: for example: Yantian port,Shenzhen,China. 518000