Dimension& Electrical Data:
N2XBY 1x(1.5-500)mm2 0.6/1kV | |||||
cross section (mm2) | outer diameter approx.(mm) | weight of cable approx (kg/km) | maximum DC resistance at 20℃ (Ω/km) | min bending radius (mm) | current rating in air at 25℃ (A) |
1×1.5 | 5.8 | 48.7 | 12.1 | 24 | |
1×2.5 | 6.2 | 60.8 | 7.41 | 32 | |
1×4 | 6.7 | 78.4 | 4.61 | 42 | |
1×6 | 7.2 | 100.4 | 3.08 | 53 | |
1×10 | 8.1 | 144.9 | 1.83 | 250 | 73 |
1×16 | 9.6 | 212.5 | 1.15 | 270 | 96 |
1×25 | 11.3 | 310.8 | 0.727 | 294 | 130 |
1×35 | 12.4 | 407.4 | 0.524 | 314 | 160 |
1×50 | 13.5 | 522.5 | 0.387 | 344 | 195 |
1×70 | 15.5 | 727.1 | 0.268 | 382 | 247 |
1×95 | 17.2 | 994 | 0.193 | 414 | 305 |
1×120 | 18.8 | 1222.8 | 0.153 | 446 | 355 |
1×150 | 21 | 1523.1 | 0.124 | 486 | 407 |
1×185 | 23 | 1860 | 0.0991 | 528 | 469 |
1×240 | 25.6 | 2405.9 | 0.0754 | 576 | 551 |
1×300 | 28.2 | 2997.4 | 0.0601 | 628 | |
1×400 | 32 | 3838.9 | 0.047 | 728 | |
1×500 | 35.6 | 4877.3 | 0.0366 | 796 |
N2XBY 2x(1.5-240)mm2 0.6/1kV | |||||
cross section (mm2) | outer diameter approx. (mm) | weight of cable approx (kg/km) | maximum DC resistance at 20℃ (Ω/km) | min bending radius (mm) | current rating in air at 25℃ (A) |
2×1.5 | 10.1 | 122.1 | 12.1 | 150 | 24 |
2×2.5 | 10.9 | 150.9 | 7.41 | 165 | 32 |
2×4 | 11.9 | 192.7 | 4.61 | 189 | 42 |
2×6 | 12.9 | 243.7 | 3.08 | 203 | 53 |
2×10 | 14.7 | 346.5 | 1.83 | 239 | 73 |
2×16 | 17.7 | 509.4 | 1.15 | 269 | 96 |
2×25 | 21.1 | 743.4 | 0.727 | 316 | 130 |
2×35 | 23.3 | 964.5 | 0.524 | 349 | 160 |
2×50 | 19.1 | 1046.1 | 0.387 | 375 | 195 |
2×70 | 21.5 | 1447.7 | 0.268 | 426 | 247 |
2×95 | 24.1 | 1985.4 | 0.193 | 501 | 305 |
2×120 | 26.7 | 2460.5 | 0.153 | 549 | 355 |
2×150 | 29.7 | 3056.8 | 0.124 | 610 | 407 |
2×185 | 32.7 | 3746.1 | 0.0991 | 666 | 469 |
2×240 | 36.9 | 4871.1 | 0.0754 | 715 | 551 |
N2XBY 3x(1.5-400)mm2 0.6/1kV | |||||
cross section (mm2) | outer diameter approx. (mm) | weight of cable approx (kg/km) | maximum DC resistance at 20℃ (Ω/km) | min bending radius (mm) | current rating in air at 25℃ (A) |
3×1.5 | 10.5 | 142.3 | 12.1 | 180 | 24 |
3×2.5 | 11.4 | 180.6 | 7.41 | 205 | 32 |
3×4 | 12.5 | 236.7 | 4.61 | 228 | 42 |
3×6 | 13.5 | 305.7 | 3.08 | 244 | 53 |
3×10 | 15.5 | 446.8 | 1.83 | 279 | 73 |
3×16 | 18.7 | 665.2 | 1.15 | 310.5 | 96 |
3×25 | 22.4 | 983.8 | 0.727 | 363 | 130 |
3×35 | 24.7 | 1291.2 | 0.524 | 396 | 160 |
3×50 | 22 | 1507.1 | 0.387 | 402 | 195 |
3×70 | 25.6 | 2129.4 | 0.268 | 480 | 247 |
3×95 | 28.6 | 2915.7 | 0.193 | 531 | 305 |
3×120 | 31.6 | 3613.7 | 0.153 | 582 | 355 |
3×150 | 35.5 | 4516.8 | 0.124 | 651 | 407 |
3×185 | 39.2 | 5538.9 | 0.0991 | 728 | 469 |
3×240 | 43.8 | 7128.8 | 0.0754 | 790 | 551 |
3×300 | 48.4 | 8965.6 | 0.0601 | 860 | |
3×400 | 55.3 | 11523 | 0.047 | 930 |
N2XBY 4x(1.5-400)mm2 0.6/1kV | |||||
cross section (mm2) | outer diameter approx.(mm) | weight of cable approx (kg/km) | maximum DC resistance at 20℃ (Ω/km) | min bending radius (mm) | current rating in air at 25℃ (A) |
4×1.5 | 11.3 | 168.8 | 12.1 | 185 | 24 |
4×2.5 | 12.3 | 217.6 | 7.41 | 205 | 32 |
4×4 | 13.5 | 289.2 | 4.61 | 227 | 42 |
4×6 | 14.7 | 379.2 | 3.08 | 244 | 53 |
4×10 | 16.9 | 561.7 | 1.83 | 279 | 73 |
4×16 | 20.5 | 843.4 | 1.15 | 312 | 96 |
4×25 | 24.6 | 1255.7 | 0.727 | 368 | 130 |
4×35 | 27.3 | 1658.4 | 0.524 | 402 | 160 |
4×50 | 25.3 | 1996.2 | 0.387 | 417 | 195 |
4×70 | 29.4 | 2819.1 | 0.268 | 469 | 247 |
4×95 | 32.8 | 3861.4 | 0.193 | 522 | 305 |
4×120 | 36.5 | 4804.6 | 0.153 | 570 | 355 |
4×150 | 40.6 | 5975.7 | 0.124 | 636 | 407 |
4×185 | 45.2 | 7364.8 | 0.0991 | 694 | 469 |
4×240 | 50.7 | 9560.4 | 0.0754 | 770 | 551 |
4×300 | 56 | 11928 | 0.0601 | 870 | |
4×400 | 63.7 | 15315 | 0.047 | 950 |
N2XBY (3+1)x(1.5-400)mm2 0.6/1kV | |||||
cross section (mm2) | outer diameter approx. (mm) | weight of cable approx (kg/km) | maximum DC resistance at 20℃ (Ω/km) | min bending radius (mm) | current rating in air at 25℃ (A) |
3×2.5+1×1.5 | 11.7 | 201.3 | 7.41 | 201 | 32 |
3×4+1×2.5 | 12.8 | 266.4 | 4.61 | 223 | 42 |
3×6+1×4 | 13.9 | 350.6 | 3.08 | 239 | 53 |
3×10+1×6 | 15.8 | 507.8 | 1.83 | 270 | 73 |
3×16+1×10 | 18.9 | 760.3 | 1.15 | 305 | 96 |
3×25+1×16 | 22.7 | 1135.5 | 0.727 | 356 | 130 |
3×35+1×16 | 24.6 | 1417.6 | 0.524 | 389 | 160 |
3×50+1×25 | 24.3 | 1779.9 | 0.387 | 435 | 195 |
3×70+1×35 | 27.9 | 2491.5 | 0.268 | 514 | 247 |
3×95+1×50 | 31.3 | 3404.1 | 0.193 | 571 | 305 |
3×120+1×70 | 34.6 | 4291 | 0.153 | 626 | 355 |
3×150+1×70 | 38.5 | 5200.7 | 0.124 | 700 | 407 |
3×185+1×95 | 42.9 | 6507.2 | 0.0991 | 762 | 469 |
3×240+1×120 | 48.1 | 8401.2 | 0.0754 | 841 | 551 |
3×300+1×150 | 53 | 10464 | 0.0601 | 956 |
Drum Data:
Certificates:
Tips:
When sending an inquiry about cables or building wires,please address the specification or parameters of cables shown as follows:
Cable name: Steel Tape Armored Power Cable Flame Retardant CU / XLPE / DSTA / PVC 0.6 / 1 KV .
Voltage: 0.6/1 KV
Cross section: for example: 3×95mm² (It means there are three conductors inside this cable and the size of each conductor is 95 square millimeters.)
Length: for example: 2000 meters
Harbor& postcode: for example: Yantian port,Shenzhen,China. 518000
It will save you a lot of time and will also help us to prepare you an accurate quotation very quickly.Thanks!