Choosing Medium-Voltage Power Cable for Industrial Substations

A practical selection guide for industrial substation buyers, covering CTT Cable’s voltage range, construction options, standards, test-report scope and quotation requirements.

Start with the industrial substation requirement

Industrial substations are one of the stated applications for CTT Cable’s Medium-Voltage Power Cable. For an EPC contractor, distributor or engineer preparing a cable enquiry, the first task is to turn the project requirement into a clearly defined specification—not simply request a generic MV cable.

CTT Cable offers single-core and three-core MV cables with rated voltages from 8.7/15 kV to 26/35 kV. The listed construction options include copper or aluminium conductors, XLPE insulation with semi-conductive screens, copper wire or tape screens, optional armour, and PVC or PE sheaths.

These options provide a starting point for an industrial substation enquiry. The final selection should be reviewed against the project specification rather than inferred from the product name alone.

Identify the required voltage and core arrangement

The published rated-voltage options are 8.7/15 kV, 12/20 kV, 18/30 kV and 26/35 kV. Buyers should state the required rating explicitly so that engineering review starts with the correct product category.

Single-core and three-core constructions are both available. An enquiry should identify the required core arrangement and conductor size, or clearly flag these details as awaiting engineering confirmation. This avoids treating different cable constructions as interchangeable during quotation review.

For a substation procurement package, keep the voltage rating, core arrangement and conductor size together in each cable line item. Where several cable requirements are included, list them separately so the proposed models can be checked against each requirement.

Define the construction options

CTT Cable lists copper or aluminium conductors for this MV cable range. The selected conductor material should be stated in the enquiry alongside the required size. If the project specification has not settled the material, identify that as an open selection point rather than leaving it implicit.

The published insulation construction is XLPE with semi-conductive screens. Screen options are copper wire or tape. Buyers should distinguish the insulation construction from the screen selection when describing the required cable.

Armour is optional, with STA or SWA listed. The available sheath materials are PVC or PE. These are construction choices, not a single standard configuration supplied for every industrial substation requirement. State the requested armour and sheath, and ask for confirmation of the proposed model during engineering review.

A clear enquiry therefore describes the complete cable construction rather than only its rated voltage. Where the specification leaves an option unresolved, mark it for review before approving the quotation or drawings.

Check standards and evidence at the correct scope

The product information lists GB/T 12706 and IEC 60502-2. Buyers should name the required standard in the procurement specification and review the supporting documentation for the proposed cable.

The supplied records include a TÜV Rheinland MV power cable test report for YJV / YJV22, 8.7/15 kV, reference 50295166 001, against IEC 60502-2:2014. Its stated scope covers 1×400 mm² and 3×400 mm², with the result recorded as Pass.

That scope matters. The report should not be presented as evidence that every voltage rating, conductor size or construction in the MV range has the same documented test coverage. Buyers should use the published scan to confirm the holder, model, issuer and scope relevant to their enquiry.

The supplied records also include low-voltage cable documentation. Those records should not be substituted for MV product evidence. IEC is a standard, not a blanket certification, and management-system certificates do not approve every product. CTT Cable’s certifications page provides a place to review published documents.

Prepare the enquiry and approval sequence

CTT Cable’s quotation process begins with the buyer sharing cable type, voltage, size, quantity and project location. For an industrial substation enquiry, add the required core arrangement, conductor material, screen, armour, sheath and standard wherever these are defined.

The next step is engineering review, during which CTT Cable’s engineers confirm the model, standards and custom options. A project-specific quotation and delivery schedule follow specification review; neither should be assumed before that review is complete.

The published process also allows buyers to order samples or approve drawings before mass production. Production and delivery tracking then extends from factory testing to shipment. Treat these as successive review stages, with unresolved specification points addressed before production approval.

FAQ

Which voltage ratings are listed for this MV cable?

The range lists 8.7/15 kV, 12/20 kV, 18/30 kV and 26/35 kV, with single-core and three-core options.

Does the supplied TÜV Rheinland MV report cover the entire range?

Its stated scope is YJV / YJV22 at 8.7/15 kV, in 1×400 mm² and 3×400 mm² configurations. Confirm documentation for the proposed project model rather than extending that scope to other configurations.

What should buyers send to obtain a quotation?

Send cable type, voltage, size, quantity and project location, together with the specified construction options and standard. Quotation and delivery timing are confirmed after specification review.

Request a project-specific quote for your industrial substation cable requirements at https://cttcable.com/contact.