YJV22 Cable Certificates: What the Published Documents Cover—and What They Do Not

A published test report is useful only when its model, voltage, standard and size scope are checked against the cable being purchased. This guide explains how to read CTT Cable’s related documents without treating them as blanket approval for every YJV22 configuration.

Start with the cable requirement, not the certificate logo

For EPC contractors, distributors and engineers, a published certificate or test report is a starting point for document review—not a substitute for matching the document to the proposed cable. The issuer matters, but so do the holder, model, voltage, standard, dimensions and validity information shown in the scan.

CTT Cable’s YJV22 Steel Tape Armoured Cable is listed as a 0.6/1 kV power cable for underground power, direct burial, outdoor feeders and industrial plants. Its construction comprises stranded copper conductors, XLPE insulation, double steel tape armour and a PVC sheath. The product listing gives two, three, four or five cores and cross-sections from 1.5 to 300 mm², with GB/T 12706 and IEC 60502-1 listed as standards.

Those details establish the product being discussed. They do not, by themselves, establish that every configuration in the listing is covered by every related document.

What the published LV test report shows

The related TÜV Rheinland LV power cable test report is titled “YJV / YJV22 0.6/1 kV.” Its reference is 50295164 001, and the listed standard is IEC 60502-1:2004. The published status identifies 1×400 mm² / 4×240 mm², with a result of Pass.

This is relevant documentation for a review of the YJV/YJV22 low-voltage cable family. However, buyers should retain the precise scope when describing it: a report with named models, a voltage rating, a standard edition and specified configurations.

The 4×240 mm² configuration falls within the core-count and cross-section range of the product listing. The 1×400 mm² configuration does not match that listed range. Neither entry should be rewritten as evidence that all two- to five-core sizes from 1.5 to 300 mm² have individually received the same reported result. Check the published scan and ask for clarification where the ordered configuration differs.

Why the MV report is a separate document

A second TÜV Rheinland report is titled “MV power cable test report YJV / YJV22 8.7/15 kV.” It carries reference 50295166 001, cites IEC 60502-2:2014, and lists 1×400 mm² / 3×400 mm², with a result of Pass.

The shared YJV/YJV22 model names do not make the medium-voltage and low-voltage reports interchangeable. The MV report identifies a different voltage rating, a different standard and different configurations from the 0.6/1 kV product listing.

For procurement review, keep these documents separate. A pass result shown for the listed 8.7/15 kV configurations should not be presented as the result for the listed 0.6/1 kV cable range.

Related documents do not necessarily cover this product

The related BSPJI Jakarta (Kemenperin RI) document is an “SNI Appendix — MV power cables,” reference LA 11540, described as an appendix to 067/W/Pro/B/III/2025. Its listed scope is CU/XLPE armoured and screened cables, 3×35–300 mm², at 6/10 kV and 12/20 kV. Those details differ from the low-voltage YJV22 listing. Review the appendix and its scope rather than assuming it approves this product.

The related CQC · CE document concerns “Ordinary PVC insulated and sheathed flexible cables.” It lists reference CE210103007098H1, EN 50525-2-11:2011, and 60227 IEC 53 (H05VV-F), 300/500 V, valid to January 2027. It is not a document for the XLPE-insulated, steel-tape armoured YJV22 product described here. Its stated validity should not be transferred to other documents.

A practical document-checking workflow

Begin with a written requirement: cable type, voltage, size, quantity and project location. Then compare each relevant scan against the proposed specification.

Check the holder, issuer, model, standard and edition, voltage, configuration, result and any validity information. Record differences explicitly instead of relying on a document title or issuer logo alone. IEC and BS are standards, not blanket certification; management-system certificates do not approve every product.

CTT Cable’s quotation process includes an engineering review to confirm the model, standards and custom options. Sales confirms the project-specific quotation and delivery schedule after specification review. Buyers can then order samples or approve drawings before mass production. This process provides an opportunity to resolve document-scope questions before placing the order.

FAQ

Does the LV Pass result cover every listed YJV22 size?

The published status names 1×400 mm² and 4×240 mm². Do not assume blanket coverage for the entire product range; verify the scan and clarify the ordered configuration.

Can the MV report replace the LV report?

No. The published reports identify different voltage ratings, standards and configurations. Use the document relevant to the proposed cable requirement.

Where should buyers verify the documents?

Review the published scans on CTT Cable’s certifications page to confirm holder, model, issuer, validity and scope.

For specification review and a project-specific quotation, request a quote from CTT Cable.

Need a quotation or datasheet for your project?

Contact CTT Cable sales