CTT Cable
← News

11/29/2026

YJV22 Cable Certificates: What Published Documents Cover—and What They Do Not

A published cable test report is useful evidence only when its model, voltage, size and standard match the requirement being reviewed. This guide explains how overseas buyers can assess CTT Cable’s published documents for 0.6/1 kV YJV22 steel tape armoured cable without assuming blanket coverage.

Start with the cable specification, not the certificate logo

For EPC contractors, distributors and engineers, reviewing cable documentation means connecting each document to the cable being purchased. An issuer’s name or a published “Pass” result is not enough to establish that every voltage rating, conductor size or construction is covered.

CTT Cable’s YJV22 Steel Tape Armoured Cable is listed as a 0.6/1 kV power cable with stranded copper conductors, XLPE insulation, double steel tape armour and a PVC sheath. The product page lists two, three, four or five cores and cross-sections from 1.5 to 300 mm². Its stated standards are GB/T 12706 and IEC 60502-1, with applications including underground power, direct burial, outdoor feeders and industrial plants.

These product details provide the starting point for document review. They should not be confused with the scope of an individual test report.

What the published low-voltage report identifies

The related TÜV Rheinland document is titled “LV power cable test report YJV / YJV22 0.6/1 kV.” Its reference is 50295164 001, and the listed test standard is IEC 60502-1:2004. The published status identifies 1×400 mm² / 4×240 mm², with a result of Pass.

This information gives buyers specific points to check: the named cable models, voltage rating, standard edition, reference number and listed configurations. It does not, by itself, establish coverage for every configuration on the current product page.

For example, 4×240 mm² falls within the product page’s listed core-count and cross-section ranges. However, that alignment alone is not a substitute for checking the report’s full scope. The report also lists 1×400 mm², while the product page lists two to five cores and cross-sections up to 300 mm². Buyers should keep the published product range and the report’s identified configurations separate.

Why the other documents need separate treatment

CTT Cable also publishes a related TÜV Rheinland medium-voltage test report for YJV / YJV22 8.7/15 kV, reference 50295166 001, against IEC 60502-2:2014. Its listed configurations are 1×400 mm² / 3×400 mm², with a result of Pass. This is a different voltage rating and standard from the 0.6/1 kV product under review.

The BSPJI Jakarta (Kemenperin RI) document is an “SNI Appendix — MV power cables,” reference LA 11540, described as an appendix to 067/W/Pro/B/III/2025. Its listed scope is CU/XLPE armoured and screened cable, 3×35–300 mm², at 6/10 kV and 12/20 kV. Those details should not be presented as approval of the listed low-voltage YJV22 range.

Another document, listed under CQC · CE, concerns ordinary PVC insulated and sheathed flexible cables. Reference CE210103007098H1 identifies EN 50525-2-11:2011 and 60227 IEC 53 (H05VV-F), 300/500 V, with validity stated to January 2027. It concerns a different cable type; its validity date should not be transferred to the YJV22 test reports.

What a published document does not automatically establish

A published certificate or report should be read according to its own wording. Management-system certificates do not approve every product. Likewise, IEC and BS are standards, not blanket certification.

For a purchasing decision, avoid treating a related document as proof of an unlisted model, size, voltage or application. A “Pass” result should remain connected to the report and configurations identified, rather than becoming a general claim that all cables are certified.

Buyers can review the published certificate scans to confirm the holder, model, issuer, validity and scope. Where those details are not established by the available information, request clarification rather than assume coverage.

Turn document review into a clear quotation request

Send CTT Cable the required cable type, voltage, size, quantity and project location. Include the applicable standard and any document requirements so the engineering review can address the intended specification.

CTT Cable’s stated process includes engineering confirmation of the model, standards and custom options, followed by a project-specific quotation and confirmed delivery schedule after review. Buyers may order samples or approve drawings before mass production. Document questions are best raised during that review, not left until the order is being finalised.

FAQ

Does the LV report cover every YJV22 size on the product page?

The supplied details identify 1×400 mm² and 4×240 mm². They do not establish blanket coverage of every listed size. Check the full report scope.

Can the MV report support the 0.6/1 kV specification automatically?

No automatic equivalence is established. The MV report identifies 8.7/15 kV and IEC 60502-2:2014, while the LV report identifies 0.6/1 kV and IEC 60502-1:2004.

What should buyers verify before ordering?

Confirm the document holder, model, issuer, validity and scope against the requested cable specification, and ask for clarification where details are missing.

To discuss your cable specification and supporting documentation, request a quote from CTT Cable.

Need a quotation or datasheet for your project?

Contact CTT Cable sales
立即询价